Home > Products > LaserSpy > LaserSpy Evaluation Unit single

LaserSpy Evaluation Unit single

TECHNICAL DATA
Item number LT72001697
Description The single evaluation unit can be used in combination with a detector unit, e.g. to monitor sliding doors or other elements where a low installation height is required.
Housing Die-cast aluminium
Schutzart IP65 in installed condition
Connecting cables 8x min. 0,34 mm² shielded
Method of operation Intermittent operation, reset after max. one month
Environmental conditions Relative humidity: < 95%.
Condensation not permitted
Air pressure: 70KPa to 106KPa
Max. Installation altitude 2000m
Ambient temperature -10 °C bis +65 °C
Storage and transport temperature -25 °C bis +85 °C
Vibration resistance 10-55 Hz, Amplitude up to 0,1 mm
Shock resistance 10 g
Weight 250 g
Response time <15 ms (in combination with a detector unit)
Radiation test pulse IR-LEDs 8 x IR-LED, max. 2 mW/sr pro LED, 880 nm up to 1000 nm
Operating voltage Ue 24VDC -/+20% up to 65m total cable length
24VDC -5%/+20% over 65m up to 100m total cable length
Power supply unit must meet SELV/PELV requirements!
Operating current Ie < 100 mA
Protection class II
Overvoltage category III
Degree of contamination 2
Rated insulation voltage U1 32 VAC/VDC
Max. control cable length depending on length of supply cable
up to max. 20m supply cable with max. 10 sensors in series max. 5m interconnection cable between each device → cable length total max. 65m
up to max. 10m supply cable with max. 10 sensors in series max. 10m interconnection cable between each device → cable length total max. 100m
Max. switching cycles over entire service life 10.000.000
Safety outputs One dual channel output
Type One potential-free contact N.O. per channel.
Max. contact current 500 mA
Min. payload 50 mW
Min. contact current 2.1 mA at 24 V
Safety assessment TÜV SÜD Rail Report ME82231T
EN ISO 13849-1:2016-06 Category 4 / PL e for 15 years’ service life (in combination with a detector unit)
PFHd = 2,79e-9/h Standard Sensor
DIN EN 61508:2011-2 SIL 3 for 15 years’ service life (in combination with a detector unit)
hardware fault tolerance 1

Contact form

    I have understood that I can take note of the data protection information here. (*)