In the modular, two-part versions of the LaserSpy sensor, the detector and evaluation units consist of separate housings that are connected via a connecting cable and form a sensor when combined. The door version detector has an extremely flat design, as the electronics are recessed into the double-walled protective element. This results in an installation height of only approx. 4 mm on the outside. In the door version, the connection between the detector unit and the evaluation unit (ideally the single evaluation unit) is made inside the protective element. The detector unit monitors a light-tight room for the entry of radiation in the respective sensitivity range of the NIR or VIS version.
Spectral sensitivity
NIR: 820nm – 1100nm VIS: 400nm – 1100nm
Response time
< 15 ms (in combination with an evaluation unit)
Max. monitoring radius
3,5 m
Weight
330 g
Degree of protection
IP65 in installed condition
Radiation test pulse IR-LEDs
8 x IR-LED, max. 2 mW/sr pro LED, 880 nm up to 1000 nm
EN ISO 13849-1:2016-06
Category 4 / PL e for 15 years’ service life (in combination with an evaluation unit) PFHd = 3.05e-9/h split sensors with single connector housing PFHd = 3.37e-9/h split sensors with quadruple connector housing
DIN EN 61508:2011-2
SIL 3 for 15 years’ service life hardware fault tolerance 1