Home > Products > LaserSpy > LaserSpy Sensor Standard NIR / VIS

LaserSpy Sensor Standard NIR / VIS

TECHNICAL DATA
Item number LT72001694 (NIR) / LT72002233 (VIS)
Description The standard version of the LaserSpy sensor combines the detector unit and the evaluation unit in one housing. The sensor allows the monitoring of a light-tight room for the entry of radiation in the respective sensitivity range of the NIR or VIS variant.
Standards, regulations EMC-Directive:
EN 50370-1:2006-02
EN 50370-2:2003-08
EN61000-6-4: 2011-09
EN61000-3-2:2017-03
EN61000-3-3:2014-03
EN61000-6-2:2006-03
DIN EN 60947-5-3:2014-12
Low-Voltage-Directive:
EN 61010-1:2011-7
Functional Safety:
EN ISO 13849-1:2016-06
DIN EN 61508:2011-2
Housing Die-cast aluminium
Degree of protection IP65 in installed condition
Method of operation optical, non-contact
Connector plug 8-pole Binder Series 423/723
Connecting cables 8x min. 0.34mm² shielded
Max. monitoring radius 3.5m around the sensor axis
(for Art. Nr. LT72001694 – LT72001699 at wavelengths between 820nm and 840nm this is valid only for a minimum laser power of 100W and untreated aluminum surfaces)
Operating mode Intermittent operation, reset after max. one month
Environmental conditions Relative humidity: < 95%.
Condensation not permitted
Air pressure: 70KPa to 106KPa
Max. Installation altitude 2000m
Ambient temperature -10 °C bis +65 °C
Storage and transport temperature -25 °C bis +85 °C
Vibration resistance 10-55 Hz, Amplitude up to 0,1 mm
Shock resistance 10 g
Weight 700 g
Response time <15 ms
Spectral sensitivity LaserSpy-4.0 NIR: 820nm to 1100nm
LaserSpy-4.0 VIS: 400nm to 1100nm
Radiation test pulse IR-LEDs  8 x IR-LED, max. 2mW/sr per LED, 880nm to 1000nm
Operating voltage Ue 24VDC -/+20% up to 65m total cable length
24VDC -5%/+20% over 65m up to 100m total cable length
Power supply unit must meet SELV/PELV requirements!
Operating current Ie < 100 mA
Protection class II
Overvoltage category III
Degree of contamination 2
Rated insulation voltage U1 32 VAC/VDC
Max. control cable length depending on length of supply cable
up to max. 20m supply cable with max. 10 sensors in series max. 5m interconnection cable between each device → cable length total max. 65m
up to max. 10m supply cable with max. 10 sensors in series max. 10m interconnection cable between each device → cable length total max. 100m
Max. switching cycles over entire service life 10.000.000
Safety outputs One dual channel output
Type One potential-free contact N.O. per channel.
Max. contact current 500 mA
Min. payload 50 mW
Min. contact current 2.1 mA at 24 V
Safety assessment TÜV SÜD Rail Report ME82231T 
EN ISO 13849-1:2016-06 Category 4 / PL e for 15 years’ service life
PFHd = 2.79e-9/h standard sensor
DIN EN 61508:2011-2 SIL 3 for 15 years’ service life
hardware fault tolerance 1

Contact form

    I have understood that I can take note of the data protection information here. (*)